5 * STAR CITY HOTEL -PUBLIC ENTRY

Luggage Room

Provide a secure room for temporary storage of guest luggage.

Size/Area: Minimum 20 m2 (215 sq. ft.) with 0.9 m (3 ft.)
wide access door

Luggage Carts: 60 x 120 cm (2 x 4 ft.). Maintain clearance and stacking capacity in room and adjacent space.

Interior Features: Provide a counter / podium near the interior of the Lobby Entrance to support hotel staff assisting guests with arrivals, departures and luggage.
• Location: Position counter / podium immediately adjacent to interior entrance to Luggage Room for efficient handling of luggage, for visual supervision of arriving / departing guests at Lobby Entrance and with visual contact with Front Desk (if possible). • Size: Minimum 0.6 m (2 ft.) wide by 1 m (3'-4") long.
• Counter / Podium: Design with lockable drawers, shelves, and include spaces for luggage tags, pens, pencils, paper, and small trash container.
• Telephone outlet. <13C>
• Lighting: Task lighting at counter with control switch.
• Finishes: Fabricate counter / podium using millwork and stone / granite countertop to complement entrance and lobby finishes.

Accessible direct from exterior and interior from Lobby.
• Position directly adjacent to interior Bellman counter / podium and exterior Car Valet Station.
• Conceal view into Luggage Room from guest (from exterior entry and interior Lobby).
• Where possible, provide a service corridor from the Luggage Room to the service elevator to avoid
transporting luggage through the Lobby.
• Provide a space or alcove, adjacent to Luggage Room and near the Bell Station, to conceal empty luggage carts to avoid visual clutter at the Lobby Entrance

 

 
 
Return to public entry main page
 
 
Google
 
Web www.iklim.com
  <
   
 
  http://www.iklimnet.com
 
Book & Magazine
Interstate Bank Fire
Beverly Hills Club Fire
MGM Fire
Firehause Magazine
Special Fires
Hotel Fires
Ship Fires
Industrial Fires
Warehouse Fires

Restaurant/Nightclub Discotheque-Fires

High Rise Fires
Fires
Fires ABC
Big Building Fires
Book About Fires
Fire Stats
Fire Board

Books About Fires

Hotels
Enviroment
Energy Save
Hotels & Legionella
Green Hotels
Hotel Design Books
Control Software