Ask The HvacMan
Air Grilles
Air Diffusers
Air Quailty
All Air Systems
All Water Systems
Boilers
Building .Managament Systems ..BMS
Burners
CAD
Chillers
Cooling Towers
Cooling Load Calculation
Cryogenics
Energy Saving
Duct
Duct ,Smacna
Dampers ,Air
Dust Collection
Fans
Fire Dampers
Glass Selection
Heating
Heat Exchangers,water
Heat Recovery
Heat Tracing Systems
Hepa Filters
Hvac Applications
Humidifiers / Dehumidifiers
Insulation , Duct
Insulation , Pipe
Insulation , Sound
Nano Tech.,In Building
Occupancy Sensors
Pneumatic Conveying
Piping
Pool Ventilation
Process Piping
Psychrometry
Pumps
Radiant Heating
Refrigerant Systems
Solar Collectors
Sound
Steam Generation
Tables & Charts Gnr.
VAV Sytems
Valves
Ventilation
VRV Systems
STORE
Solar Collectors
Flat Plate Collectors
Evacuated Tube Collectors
Concentrating Collectors
Transpired Collectors
Solar Control Systems
Standalone Systems
Grid Connected Systems
Hybrid Systems
Back-up Systems
Solar Cells
Solar Arrays
Inverters
Change Controller
Turbines
Hybrid Systems
Grid Systems
Water Pumping
Using Wind Energy
Enviromental Aspects
Buyer's Guide
Fire Exit Systems
Save Energy
Solar Water Heating
Solar Electric Systems
Wind Turbines
Passive Solar Heating
Passive Solar Cooling
Building Material
Water Conservation
Ground Source Heat-Pumps
Green Hotels

Glass &Windows Selection

Hotels ,Motels ,Equipments, Piping
Piping


Service Material Type Weight
       
Steam through      
250mm Steel Black Schedule 40
300mm & up Steel Black 375 in. wall thickness
       
Condensate
Return & Drip
Steel Nickel Schedule 40
       
Condensate
Pumped
Steel Nickel Schedule 40
       
Chilled &
Condensing
Water through
     
250mm Steel Black Schedule 40
300mm & up Steel Black 375 in. wall thickness
       
Fan Coil
Unit Drains
Plastic ABS  
       
       
       

Hangers and Supports

All pipes shall be supported with adjustable hangers of size and spacing as follows:

Pipe Size Hanger Spacing (Max.) Rod Size

Up to 25mm 1.8m 9.5mm
32mm to 50mm 2.8m 9.5mm
65mm to 100mm 3.0m 12.5mm
150mm and larger 3.7m 12.5mm

Hangers shall be secured to building steel with beam clamps or to floor slab with malleable iron inserts.

Vibration type hangers shall be provided within 15 meters of all rotating equipment and pressure reducing valves.

 

 
Back to Hotels
Back to Hvac Expert Main Page

 

 

 

 