Ask The HvacMan
Air Grilles
Air Diffusers
Air Quailty
All Air Systems
All Water Systems
Boilers
Building .Managament Systems ..BMS
Burners
CAD
Chillers
Cooling Towers
Cooling Load Calculation
Cryogenics
Energy Saving
Duct
Duct ,Smacna
Dampers ,Air
Dust Collection
Fans
Fire Dampers
Glass Selection
Heating
Heat Exchangers,water
Heat Recovery
Heat Tracing Systems
Hepa Filters
Hvac Applications
Humidifiers / Dehumidifiers
Insulation , Duct
Insulation , Pipe
Insulation , Sound
Nano Tech.,In Building
Occupancy Sensors
Pneumatic Conveying
Piping
Pool Ventilation
Process Piping
Psychrometry
Pumps
Radiant Heating
Refrigerant Systems
Solar Collectors
Sound
Steam Generation
Tables & Charts Gnr.
VAV Sytems
Valves
Ventilation
VRV Systems
STORE
Solar Collectors
Flat Plate Collectors
Evacuated Tube Collectors
Concentrating Collectors
Transpired Collectors
Solar Control Systems
Standalone Systems
Grid Connected Systems
Hybrid Systems
Back-up Systems
Solar Cells
Solar Arrays
Inverters
Change Controller
Turbines
Hybrid Systems
Grid Systems
Water Pumping
Using Wind Energy
Enviromental Aspects
Buyer's Guide
Fire Exit Systems
Save Energy
Solar Water Heating
Solar Electric Systems
Wind Turbines
Passive Solar Heating
Passive Solar Cooling
Building Material
Water Conservation
Ground Source Heat-Pumps
Green Hotels

Glass &Windows Selection

Designing Eco-Hotels,Strategies for an improved hotel environment.
 

Strategies for an improved hotel environment.

ENVIRONMENTAL OBJECTIVE

STRATEGY

COMMENT

Improved air quality

Ducted primary air in lieu of infiltration or operable windows Add thermal/latent recovery units between toilet exhaust and outside air.
Improved unit air filtration Use mini-pleats in lieu of cleanable/throwaway filters.
Control source content Avoid use of materials with VOCs and contaminants.

Energy conservation

Improved controls Allow setbacks and drift in unoccupied rooms.
Geothermal systems Consider when resource is available.
Energy recovery Use on all air systems.
Capture waste heat from laundries and process equipment.
Passive energy systems Naturally temper outside air.
Natural energy sources Investigate wind, solar, and water power.

Water conservation

Low-water-flow fixtures and fittings Provide automatic operation when possible.
Recycled grey water for non-potable uses Use environmentally responsive treatment processes.
Use HWAT in lieu of hot-water circulation Minimize lengths of uncirculated hot-water pipe.
Store/reuse rain water Do if storage space is available.

Environmental conditions

Individual thermal control Provide as many zones as possible.
Humidity control Provide close tolerance summer and winter control.
Acoustical environment Select quiet equipment.
Control duct/air/pipe/water noise.
Use controls to permit "low-speed" operation.
Air motion Avoid drafts and "dead" spots.

 

 