HVAC
Building Control
Fire Safety
Your friend in indoor comfort & safety systems
Home Company Services Case Studies References Agencies Daikin-Vrv Handbook Fires / Hotels AskHvacMan Links Save Energy Contact Us
Fires &
Dictionary
Fire ABCs
Sprinklers
Some Fire Cases
Fire Books
Software
FireBoard
Hotels

Big Hotel Fires

Fire Safety
Detection
Suppression
Hotel Fire Case
Inspection
How to Survive
FireStats
Big Hotel Fires
Hotel Fire Cases
Fire Hazard Classification
Hotel Sprinkler Systems

Hotel Fire News

Special Fires
Hotel Fires
Ship Fires
Industrial Fires
Hospital Fires
Warehouse Fires

Restaurant/Nightclub Discotheque-Fires

High Rise Fires
Airport Fires
Fires
Fires ABC
Big Building Fires
Book About Fires
Fire Stats
Fire Board

Books About Fires

Fire Exit Systems
Software About Fires
Fire Sprinkler Software
Fire Egreess Software
Fire Modelling Software
Sprinkler
What is Fire Sprinkler
Success Stories
Sprinkler Manufacturers
Fire Pump Manufacturers
Standar for Sprinkler Systems
Sprinklered Hotels

Books About Sprinkler

Glossary
Definitions
Manufacturers
Basic
Why
Systems
Public Entry
Recration Areas
 Retail Areas
 Function Spaces
 Guestrooms
Hauskeeping
Elavators
Foods & Beverage
Mechanic Systems
Fire Protection
Kitchen
Site Development
 
 

Fire Sprinkler Design Software

Egress Software
Modelling Software

ECHOSCAN

FIRE SPRINKLER SYSTEM DESIGN (IBM & compatibles) CAT.# 148-D01-38

    FSTLD interactively works with the designer to develop fire sprinkler systems
    of the tree and loop types. It employs the NFPA formulas and calculation
    procedures to produce printouts. In the NFPA "Manual 13" format, ready for
    presentation to Underwriters for approval.

    For each section you may specify the sprinkler head "K" value; Hazen-Williams
    "C" factor; elevation; and pipe length. Additional hose flows may be included
    at any point. Calculation of flows from each head is automatic. "K" values
    are constantly recalculated for the downstream portion of the system and may
    be re-used to eliminate detailed inputs for similar branch lines. FSTLD also
    derives the equivalent pipe length for simple parallel pipe supply lines.
    Included are data files for internal pipe diameters, "C" factors, and
    equivalent lengths of fittings.

    For deluge systems, FSTLD can handle up to 20 flowing lines, each with 20
    pieces. There are windows, over 100 help screens and error checks for range
    and type. Data entry, editing, storage and retrieval are fully prompted, with
    defaults values supplied wherever possible. Data is saved in named job files
    for later recall and change.

    Requires 448K RAM and an 80 column (or wider printer).

 
 
 
  http://www.iklimnet.com
 
Air Grilles
Air Diffusers
Air Quailty
All Air Systems
All Water Systems
Boilers
Building .Managament Systems ..BMS
Burners
Chillers
Cooling Towers
Cooling Load Calculation
Cryogenics
Energy Saving
Duct
Duct ,Smacna
Dampers ,Air
Dust Collection
Fans
Fire Dampers
Glass Selection
Heating
Heat Exchangers,water
Heat Recovery
Heat Tracing Systems
Hepa Filters
Hvac Applications
Humidifiers / Dehumidifiers
Insulation , Duct
Insulation , Pipe
Insulation , Sound
Nano Tech.,In Building
Occupancy Sensors
Pneumatic Conveying
Piping
Pool Ventilation
Process Piping
Psychrometry
Pumps
Radiant Heating
Refrigerant Systems
Solar Collectors
Sound
Steam Generation
Tables & Charts Gnr.
VAV Sytems
Valves
Ventilation
VRV Systems