HVAC
Building Control
Fire Safety
Your friend in indoor comfort & safety systems
Home Company Services Case Studies References Agencies Daikin-Vrv Handbook Fires / Hotels AskHvacMan Links Save Energy Contact Us
Fires &
Dictionary
Fire ABCs
Sprinklers
Some Fire Cases
Fire Books
Software
FireBoard
Hotels

Big Hotel Fires

Fire Safety
Detection
Suppression
Hotel Fire Case
Inspection
How to Survive
FireStats
Big Hotel Fires
Hotel Fire Cases
Fire Hazard Classification
Hotel Sprinkler Systems

Hotel Fire News

Special Fires
Hotel Fires
Ship Fires
Industrial Fires
Hospital Fires
Warehouse Fires

Restaurant/Nightclub Discotheque-Fires

High Rise Fires
Airport Fires
Fires
Fires ABC
Big Building Fires
Book About Fires
Fire Stats
Fire Board

Books About Fires

Fire Exit Systems
Software About Fires
Fire Sprinkler Software
Fire Egreess Software
Fire Modelling Software
Sprinkler
What is Fire Sprinkler
Success Stories
Sprinkler Manufacturers
Fire Pump Manufacturers
Standar for Sprinkler Systems
Sprinklered Hotels

Books About Sprinkler

Glossary
Definitions
Manufacturers
Basic
Why
Systems
Public Entry
Recration Areas
 Retail Areas
 Function Spaces
 Guestrooms
Hauskeeping
Elavators
Foods & Beverage
Mechanic Systems
Fire Protection
Kitchen
Site Development
 
Water Mist V Sprinklers
SYSTEM TYPE Reactive
Surface Area
Per 1ltr Water
Visibility
During
Operation
Operating
Temp Of
Auto Nozzles
Operating
Sensitivity / Speed
(R.T.I)
Water Usage
Average Per
Head LPM
Run Time
From Water Storage
4 heads Operating
Dual Systems
Life Safety
Support
Density Of
Head Spacing
Up To 5m
System
Design
Objective
Smoke
Control
(Scrubbing)
Installation
Height
Restriction
Use on various types
of fire i.e liquid fat
Life Safety Sprinklers
BS 5306 Part 2
2m² Good 57-68ºc Fast Response
3mm Bulbs
40-50
60 LPM 60 Minutes Yes 3-4m Fire Control Poor No No
Residential & Domestic
Sprinklers BS9251
2m² Good 57-68ºc Fast Response
3mm Bulbs
40-50
60 LPM 15 min Domestic
30min Residential
No
Single Pump
3-4m Fire Control Poor Yes 22m No
LP-2000 Life Safety
Low Pressure Water
Mist
2500m² Good 57-68ºc Extra Fast Response
2.5mm Bulbs
27-31
Varies
Dependant Upon
Ceiling Height
8.0-21 LPM
15 min Domestic
30-60 min Residential
60 min Commercial
Yes 2-3m Fire Suppression
Extinguishment
Good No Yes
High Pressure Fog
Systems
3000-6000m² Poor 57-68ºc Extra Fast Response
2.5mm Bulbs
27-31
8 LPM 30 Minutes Yes 2-3m Fire Suppression
Extinguishment
Very
Good
Yes due to
water
velocities
approx 60m
Yes
 
 
 
 
 
 
 
 
  http://www.iklimnet.com
 
Air Grilles
Air Diffusers
Air Quailty
All Air Systems
All Water Systems
Boilers
Building .Managament Systems ..BMS
Burners
Chillers
Cooling Towers
Cooling Load Calculation
Cryogenics
Energy Saving
Duct
Duct ,Smacna
Dampers ,Air
Dust Collection
Fans
Fire Dampers
Glass Selection
Heating
Heat Exchangers,water
Heat Recovery
Heat Tracing Systems
Hepa Filters
Hvac Applications
Humidifiers / Dehumidifiers
Insulation , Duct
Insulation , Pipe
Insulation , Sound
Nano Tech.,In Building
Occupancy Sensors
Pneumatic Conveying
Piping
Pool Ventilation
Process Piping
Psychrometry
Pumps
Radiant Heating
Refrigerant Systems
Solar Collectors
Sound
Steam Generation
Tables & Charts Gnr.
VAV Sytems
Valves
Ventilation
VRV Systems